ACIST HDi®
HD IVUS Console

ACIST HDi High-Definition IVUS System enables optimized visualization to inform and illuminate coronary and peripheral intervention strategy through advanced imaging modes, improved deliverability of the Kodama IVUS Catheter and interactive compact console.

See more with ACIST HDi

Providing you the power to see with certainty.

LumenView™

Darkens the coronary lumen for better border detection.

SilkView™

Increases gray scale for finer blood speckle, tissue and plaque differentiation.

ClassicView™

Optimizes the balance of high resolution and depth of penetration and enables full vessel wall visualization.

Coronary IVUS

Clinical Evidence

Better visualization of media than OCT for optimizing stent sizing4

Enables enhanced imaging by providing sufficient penetration at 60 MHz to see the media layer, even in larger plaque volumes, so the physicians can maximize the stenting cross sectional area and may lead to better patient outcomes5

IVUS Use changed the treatment strategy duMHzR8ring the procedure 74% of the time6

IVUS-guided stents also had low proximal & distal plaque burden, & higher MSA compared to the angio-guided group7

8x more detection of lipid pools at 60 MHz than 40 MHz8

IVUS-guided PCI is beneficial for preventing the Stent Edge Restenosis in cases with diffused plaque lesions compared to angiography alone9

IVUS is less expensive and more cost effective than angiography in 71% of PCI procedures1o

IVUS provides improved outcomes at lower costs, with greater economic benefit especially in higher risk subgroups (diabetes, renal insufficiency, ACS)

This is based on a lifetime economic model from Italian healthcare payer perspective10

See the Difference. Visualize with Confidence.18

Peripheral IVUS

Clinical Evidence

Use of IVUS in lower extremity procedures was associated with lower risk of complications post-procedure and lower risk of amputation11

2.8x less target lesion revascularizations at one-year follow up when using IVUS in directional atherectomy procedures compared to angiography alone12

Visual estimation measurements obtained from angiographic images were consistently smaller across all arterial segments than those obtained from IVUS assessment13

69% more calcium detected by IVUS compared to angiography in the sane lesions14

2x more thrombus identified by IVUS compared to angiography15

4x more post-stent dissections were identified by IVUS compared to angiography16

3.5x more post-angioplasty dissections were identified by IVUS compared to angiography17

6x more post-atherectomy dissections were identified by IVUS compared to angiography17

See the Difference. Visualize with Confidence.18

References

Rx Only
Prior to use, reference Instructions for Use, inside the product carton (when available) or at < enterwebsite.com> for more detailed information on safe use of the device.

Indications for Use:
The ACIST HDi® System is intended to be used for the ultrasound examination of coronary and peripheral intravascular pathology. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal interventional procedures. The ACIST Kodama Intravascular Ultrasound Catheter is intended for use with the ACIST HDi System.

Contraindications:
Contraindicated for patients with: bacteremia or sepsis; arterial spasm; major coagulation system abnormalities; mechanical heart valves that would be crossed by the catheter; severe hemodynamic instability or shock; total vessel occlusion (prior to initial stages of revascularization). Contraindicated for use in the cerebrovascular arteries. In coronary procedures, the product is also contraindicated for patients who are: disqualified for revascularization surgery; disqualified for balloon angioplasty (PTCA).

Important Safety Info:
Intravascular ultrasound studies using this product should be performed only by physicians and other medical professionals fully trained in the required techniques and procedures.The Kodama catheter contains a short monorail guidewire engagement system. As such, it is susceptible to guidewire entanglement and/or prolapse during catheter deployment and withdrawal. Before use and when possible during use, inspect the Kodama catheter carefully for kinks or any other damage. Do not use a kinked or damaged catheter because vessel damage and/or the inability to advance or withdraw the catheter may occur.

Never advance or withdraw the Kodama catheter against resistance until the cause of the resistance is determined by fluoroscopy. Movement of the catheter or guidewire against resistance may result in elongation or separation of the catheter or guidewire tip, damage to the catheter, or vessel perforation.

When advancing the Kodama catheter through a stented vessel, short monorail catheter designs are susceptible to guidewire/ catheter entrapment, catheter tip separation, and/or stent dislocation.
Adverse events that may occur as a consequence of intravascular ultrasound imaging include (but are not limited to): vessel occlusion and/or abrupt closure; air embolism; vessel dissection, injury, or perforation; vessel rupture, injury, or perforation; acute myocardial infarction; cardiac arrhythmias including but not limited to ventricular tachycardia, ventricular fibrillation, and complete heart block; cardiac tamponade; catheter/guidewire entrapment; catheter induced ischemia; death; vessel trauma requiring treatment/surgical intervention, including angioplasty/stent; infection; stent strut damage; stroke (including cerebral vascular accident and transient ischemic attack); thrombus formation or thromboembolism; vasospasm.